Main features
* Latest interrnational standard:Comply with CCC,IEC,EN VDE,BS,UL,JIS,standard requirements.
* Three and Single phase(300V/23A) leakage current test
* 7 kings of built-in networking MD card for leakage current test
* 8 kinds of visual programmable settings of DUT power input
* 3 test modes.L,N to GND,surface to surface and L,N to surface
* Upper/Lower limits judgment,test wires compensation,intelligent protection
* User pass word and keyboard lock function
* 8 groups of test memories,8 programming steps for each group
* 5.4 LCD display,menu operation.
Order infomation and extended functions
* AN9620TH(F),three/single-phase load compatible,multiple network leakage current test.
* AN9620H(F), single-phase load,multiple network leakage current test.
Spec.
| Leakage currentgrounding current test |
| Load type |
AN9620H(F) |
Single phase 6kWstatic and dynamic leakage test |
| |
AN9620TH(F) |
Single phase 6kW/triphase 20kWstatic and dynamic leakage test |
| Alarm current setting |
Range |
With MD network automatic identification function
B network018.00mAE network06000 uA
G network04500 uAother network09000uA
0 means do not make judgment |
| Test time setting |
RangeAccuracy |
01.0999.9s0 for infinite length3%setting+0.1s |
| Leakage current measurement |
Range
Resolution |
10.0uA999.9uA0.1uA
1000uA9999uA1uA
10.00mA18.00mA0.01mA |
| Accuracy |
10uA50uADC1MHz2%reading+3uA
50uA18mADC10kHz2%reading +0.5uA
10k200kHz5%reading +0.5uA
200k1MHz5%reading +1.5uA
RemarksG network 1050uAaccuracy 2%+12uA50uA100uAaccuracy2%+4uA |
| DUT parameters |
Voltage range Accuracy |
30.0300.0Vsingle phase1%reading+0.5V |
| Current range |
023A/ACover current protection is 25A |
| Extended function |
| Communication function |
Address setting |
1-255 |
| Baud rate setting |
3001200240048009600192000 |
| Verification mode setting |
Noneoddeven |
| Operation interface |
Display screen |
320*240 LCD show |
| Interface language |
ChineseEnglish |
| Alarming voice |
ON/OFF |
| Password protection |
Four password Settingspassword function can be set to ON/OFF |
| Interface function |
| Communication interface |
Standard RS232. LANRS485GPIB are optional |
| PLCinterface |
standardcan output startstoptestpassfail |
| Printer interface |
standardparallel printing interface |
| Remote control interface |
optionalmanual remote control boxstartstop |
| General specification |
| Operating environment |
04040/2075% RHlittle dust |
| Storage environment |
406050/2090% RHlittle dust |
| Power requirements |
220V10%50Hz5%10A |
| Power Consumption |
100200VArelated to working condition |
| Grossweighwith packing |
About 15kg |
| Dimensionmmwith packing |
570(W)340(H)660(D) |
| Dimensionmmwithout packing |
400(W)156(H)475(D) |